2000 Series Portable Calibration Instrument

Buy Now
Download Data Sheet

Vitrek’s XiTRON 2000 Series of portable calibrators is field proven. These rugged devices are built for reliability from the ground up. The devices push the envelope for DC calibration, temperature simulation and measurement accuracy. Both models are available with battery-powered options.

These versatile and portable calibrators bring laboratory accuracy to process control applications. Current loop (4 – 20 mA) indicators, controllers and recorders can be calibrated with accuracy measured in ppm rather than percentages.

The 2000 Series instruments may compute current or voltage output using an equation derived from two data points. This allows the user to enter a temperature, pressure or fl ow level and the 2000 will output the appropriate current or voltage signal.

The highly versatile 2000MN adds temperature measurement and automatic cold junction compensation to the impressive list of features. It allows the user to read or source in °C or °F for B, E, J, K, N, R, S and T thermocouples.

Compact and economical, the 2000 Series provides the right combination of accuracy and flexibility for most temperature measurement/simulation applications. These portable, precision instruments address a wide cross-section of calibration requirements.

Temperature measurement may automatically compensated for the cold junction temperature.

Simulates DC output of pressure transducers for calibrating systems.

Ordering & Accessories

Below prices in US$ are for destinations in North America with terms of prepay, net 30 days (OAC) and accepted credit cards. For shipment beyond North America or terms beyond 30 days, please contact the factory for a quotation.

Portable Calibration Units

2000IN

2000 Series Portable Calibration Instrument. DC Voltage and Current Calibrator. Includes RS-232 interface and Universal-Free Standing Charging Adapter

$3,025.00

2000MN

2000 Series Portable Calibration Instrument. DC Voltage and Current Calibrator with Temperature Simulation and Voltage / Temperature Measurements (Active or Passive CJC), includes RS-232 interface and Universal Free-Standing Charging Adaptor

$3,695.00

Portable Calibration – Options & Accessories

Placeholder

2000-IE-BAT

2000 Series Portable Calibration Instrument Option IEEE-488 Interface

$435.00
Placeholder

2000-MEM

2000 Series Portable Calibration Instrument Option 10-Step Output Level Memory

$210.00
Placeholder

2000I OPT NB

2000 Series Portable Calibration Instrument Option No internal battery option at time of order (Typically used in ATE applications)

$0.00
Placeholder

2000M OPT NB

2000 Series Portable Calibration Instrument Option No internal battery option at time of order (Typically used in ATE applications)

$0.00
Placeholder

BAT0001

Battery, Sealed Lead Acid, 3.4AHr

$55.00
Placeholder

BAT0002

Battery, SNIMH, 4.2AHr

$70.00

CC-2000

2000 Series Portable Calibration Instrument Option Canvas Carrying Case with Charger and Lead Pocket

$155.00
Placeholder

GPIB-IEEE-488-ADAPTER

IEEE-488 Adapter

$962.00
Placeholder

PL36-2000

36" Long, Low Thermal EMF Red & Black Lead Set (Plugs)

$60.00

RA-2000

2000 Series Portable Calibration Instrument Option Single Instrument Rack Adapter

$275.00

RB-2000

2000 Series Portable Calibration Instrument Option Three  Instrument Rack Adapter

$385.00
Placeholder

RC-2000

2000 Series Portable Calibration Instrument Option Two Instrument Rack Adapter

$350.00
Placeholder

SG2000

2000 Series Portable Calibration Instrument Service Guide w/Schematics, Theory of Operation and Calibration Procedure

$26.00

SP48-2000

48" Long, Low Thermal EMF Shielded Lead Set (Spade Terminals)

$85.00
Placeholder

SVCC-AMS2750D

2000 Series Portable Calibration Instrument Calibration Option AMS2570D Calibration for 2000MN with Data

$825.00
Placeholder

SVCC-MIL-2000I

2000 Series Portable Calibration Instrument Calibration Option Post Data Calibration at time of order - 2000 Series Calibration Instrument.

$345.00
Placeholder

SVCC-MIL-2000M

2000 Series Portable Calibration Instrument Calibration Option Post Data Calibration at time of order - 2000 Series Calibration Instrument.

$345.00

T5

Universal Free-Standing Charging Adapter

$120.00
Placeholder

UG2000

2000 Series Portable Calibration Instrument Additional Operating Manual Set

$26.00

Portable DC Calibration – TC Simulation – Temperature Measurement

These versatile and portable calibrators bring laboratory accuracy to process control applications. Current loop (4 – 20 mA) indicators, controllers and recorders can be calibrated with accuracy measured in ppm rather than percentages.

The 2000 Series instruments may compute current or voltage output using an equation derived from two data points. This allows the user to enter a temperature, pressure or flow level and the 2000 will output the appropriate current or voltage signal.

The highly versatile 2000MN adds temperature measurement and automatic cold junction compensation to the impressive list of features. It allows the user to read or source in °C or °F for B, E, J, K, N, R, Sand T thermocouples.

Compact and economical, the 2000 Series provides the right combination of accuracy and flexibility for most temperature measurement/simulation applications.

These portable, precision instruments address a wide cross-section of calibration requirements.

Temperature measurement may automatically compensated for the cold junction temperature.

Simulates DC output of pressure transducers for calibrating systems.

Product Features and Benefits

  • Excellent performance and flexibility in portable, battery-operated applications
  • DC voltage and current capability — +/- 22 volt, 10ppm accuracy, +/-22mA, 40ppm accuracy
  • Temperature simulation with 0.01°resolution, 0.015°- 0.12° accuracy (90 day)
  • DC resolution down to 10nV or 10pA
  • Temperature measurement with 0.1°-0.2° accuracy (90 day)
  • Auto cold junction compensation NiMH battery operation (8 hours typical)
  • Battery powered portability for flight line use
  • Standard RS232 interface allows laptop PC control in the field while the optional IEEE-488 interface supports ATE applications.
  • Temperature control loops
  • Thermocouple measurement and simulation
  • Battery status indication

Self Calibration Feature

An automatically sequenced Internal Self-Calibration may be performed at any time. This procedure does not require any external equipment or connections. The accuracy specification assumes the use of this procedure at least every five days, or following an ambient temperature change of greater than 5 degrees C.

An automatically sequenced External Calibration may be performed at any time. In order to prevent unauthorized access, an optional password protection scheme is utilized. A one year external calibration cycle is recommended for normal use, however, this may be reduced (e.g. to three months) if increased accuracies are required, or increased (e.g. to two years) if reduced accuracies are required.

External Calibration may be performed at any ambient temperature between 10 degrees C and 35 degrees C without degradation of the accuracy specifications, the accuracy figures then being valid for ambient temperatures of up to 5oC from this calibration temperature.

Specifications

General Specifications – For Full Specifications contact Vitrek

Physical: SIZE: 4.1” W x 6.3” H x 9.7” D (104mm x 160mm 246mm) Weight: 4.5 lbs

Environmental
Operating: 0°C to 50°C, less than 90% R.H.(typ) at 40°C (non-condensing)
Storage: -30°C to 65°C, less than 95% R.H. at 40°C (non-condensing)

Isolation: Output to Chassis, Ground or Interface: 1500V pk max.Unit is supplied with one Vitrek T5 universal external power supply, 100-240 Vrms, 50-60Hz, with a 2.5mm 12 VDC output plug and a three-prong IEC320 AC Inlet receptacle, plus a three-prong AC power cord.

Warranty: Two Years

Rentals

The 2000 Series Portable Calibration Instruments and accessories are available for rent. Please contact the factory for a rental quotation on the items and period of time you desire. Vitrek offers a generous rental allowance for rentals that are converted to a purchase and rentals of 12 months come with a 10% buyout.

2000 Series Downloads

Download Data Sheet
Download Manual
Download 2000 Data Collection App
* This is an engineering app that plots the display of a 2000. Source 99k

Download 2000 Output Log
* This was written in C for DOS computers. It logs the output of a 2000 display to a file. Note: The RS232 routines were provided by Bri Productions serial port communications software CPORT. All Rights Reserved.

Download 2000 Read Me File
* This is the readme file.

Download 2000 Source Code
* This is the 2000 Source Code.

*Note there is no upgradeable firmware in this product.