280X-RB-255X

280X Power Analyzer Option – Rack Adapter

SKU: 280X-RB-255XCategories:

280x Series Single- and Two-Channel Power Analyzers

With an extended measurement range from micro-amps to hundreds of amps and millivolts to kilovolts, the 2801 & 2802 are the ideal analyzers for standby power or Energy Star testing. In addition to numerical results, the 2801 & 2802 captures waveforms with true 512-point precision. Results and waveforms can be displayed, read via communication ports or sent directly at full resolution to a USB printer. Power and amplitude measurements with an accuracy of <0.1% are automatically synchronized to the fundamental frequency. Peak, RMS, rectified and DC measurements of voltage, current and power are provided including continuous, inrush, startup and history modes, plus an integration mode for W-Hr, A-Hr, VA-Hr as well as integrated average power. (Channels can be operated synchronously or independently on the 2802). The 2801 and 2802 also provide waveform peak and glitch capture modes.

Product Features and Benefits

  • Highest Performance to cost ratio in the industry
  • Up to 2000V peak and 150A peak measurable internally (external CT capable)
  • 2802 Model Equipped with Two Channels for independent or synchronous measurements, including input/out efficiency and loss
  • Base accuracy <0.08%. Current and voltage accuracies specified to less than 1mArms and 1Vrms respectively (<0.2%)[/fusion_li_item] [fusion_li_item icon=""]Measures & Displays volts, current, power frequency, harmonics (to the 100th), THD, PF, CF, K-Factor, Triplens, inrush, distortion, glitches and much more
  • Integrated line switch and inrush waveforms
  • Source or load measurements with wiring loss and voltage burden compensation
  • DC Charge and discharge measurements
  • Frequency range: DC and 20mHz-200kHz
  • Graphic Display shows numerical results, waveforms, bar graphs, startup and history charts with zoom & scroll features
  • 16-bit A/D converters at 235ksps
  • 12 User-configurable digital I/O
  • USB Flash Drive Support for data logging
  • Communications interfaces include: GPIB (IEEE488), RS-232, USB (host and device)
  • 2802 Model suitable for AC, DC, 1-phase 3-wire, 2-phase 3-wire, 3-phase 3-wire, in out synchronous or independent measurements

Specifications

General Specifications – For Full Specifications contact Vitrek

Accuracy specifications valid for one year for ambient temperatures within 5 °C of calibration temperature.

Voltage Range (Measureable): 2000V (850Vrms) max. continuous

Internal Current Range (Measurable): 150Apk (30Arms) max. continuous

External Current Transducers (Measurable): 35Vpk (15Vrms) max. continuous

Voltage & Current Accuracy: See charts below

Frequency Measurement Accuracy: 0.005%

Crest Factor Accuracy: V: (50mV + 0.01% of pk rng)/RMS value   A: 50uA + 0.01% of pk rng)/RMS value

Harmonic Accuracy (Voltage & Current): 0.02%

Waveforms: Actual, Peak Capture, Distortion and Glitch Capture

Charts, with Zoom & Scroll: History, Startup and Inrush

Line Switch
Max Open Voltage: 720Vpk (480Vrms)
Max Surge Current: TBD
Max On Current: 10Arms
Turn On Phase: 1° resolution

Digital Interfaces: GPIB (IEEE-488), USB (host and device), RS-232, Digital IO

Physical
Power Input:
12VDC @ 1.5A minimum output
Size:
(HxWxD) 4.7″ x 13.8″ x 9.5″ (11.94cm x 35.05cm x 24.13cm)
Weight: 7.5 lbs
Operating Range: 0°C to 55°C, less than 95% R.H. (non-condensing)
Storage Range: -20°C to 670°C, less than 95% R.H. (non-condensing)

Unit is supplied with one Vitrek T5 universal external power supply, 100-240Vrms, 50-60Hz, with a 2.5mm 12VDC output plug and a three-prong IEC320 AC inlet receptacle, plus a three-prong AC power cord.

Warranty: Two Years

Ordering & Accessories

Below prices in US$ are for destinations in North America with terms of prepay, net 30 days (OAC) and accepted credit cards. For shipment beyond North America or terms beyond 30 days, please contact the factory for a quotation. If you require rush/expedited shipment please contact Vitrek at (858) 689-2755 or email info@vitrek.com

280x Power Analyzers

280x Power Analyzer Options & Accessories

Rentals

The 280x Series Power Analyzers and accessories are available for rent. Please contact the factory for a rental quotation on the items and period of time you desire. Vitrek offers a generous rental allowance for rentals that are converted to a purchase and rentals of 12 months come with a 10% buyout.

280X Series Downloads

3.8M zip file – This zip file contains the latest 280x USB driver for 32-bit operating systems. This file includes the DLL. 01 Apr 2009

3.9M zip file – This zip file contains the latest 280x USB driver for 64-bit operating systems. This file includes the DLL. 01 Apr 2009

This PDF lists the function calls to the DLL 12-June-2012

470k, USB, LabView 8.6.1 – This software displays many of the 280x parameters on a single screen, allows for snapshot recording of the data or continuous logging of data to an Excel-compatible file. It also displays the harmonics and distortion graphs.

560k, USB, LabView 8.2 – This XView software is based on LabView 8.2. It automates the data collection and reporting for the ENERGY STAR Program Requirements for Computers: Version 4.0 – 19 Sept 08

492k, USB, LabView 8.2- This XView software is based on LabView 8.2. It automates the data collection and reporting for the ENERGY STAR Program Requirements for Consumer Audio and DVD products. The zip file also includes the ENERGY STAR requirements document. 02 July 2007

281k, USB, LabView 8.2- This XView software is based on LabView 8.2. It automates the data collection and reporting for the ENERGY STAR Program Requirements for single-voltage, external AC/DC and AC/AC power supplies.

167k, USB, LabView 8.2- This XView software is based on LabView 8.2. It automates the data collection and reporting for the ENERGY STAR Program Requirements for 03 Nov 2008