RE

RE – Rack Adapter Kit

6250/6000 Series Phase Angle Voltmeters

Using the most advanced digital signal processing technology, Vitrek’s family of phase angle voltmeters delivers true accuracy and versatility at the touch of a button. Phase Angle Voltmeters provide direct readouts of phase insensitive, phase sensitive and harmonic data. Units automatically calculates and displays results. Self-calibration and testing capability ensures the most accurate results possible.

Model 6250

The 6250 comes pre-configured for most LVDT/RVDT tests, and is ready to go – right out of the box. The instrument requires less set-up and maintenance than competing products. And, because of its simplicity of operation, the 6250 can be used by virtually anyone who wants access to results more quickly and more reliably.

Features
  • Wide Bandwidth (0.1Hz to 100 kHz).
  • 0.05% basic amplitude accuracy and 0.05° phase accuracy
  • 0.01% + (0.03% divided by measurement period) frequency measurement accuracy
  • Front panel configuration lockout for dedicated production and QC test applications
  • Can be configured to emulate analog PAVs

Model 6000
The 6000 Series PAVs use the latest DSP technology to deliver true accuracy, versatility and portability without the cost and reliability burdens of older technologies.

Features
  • Wide Bandwidth (0.1Hz to 100kHz).
  • 0.05 % Basic Amplitude Accuracy.
  • 0.05° Phase Accuracy.

Product Features and Benefits

    Model 6250

  • Wide bandwidth (0.1Hz – 100kHz)
  • 0.05% basic amplitude accuracy
  • 0.05° phase accuracy
  • Total & Individual harmonic analysis
  • 110ppm accuracy, 1ppm resolution, frequency measurements
  • 4-line scrollable (50 lines total) display and 101 element multimeter
  • Separate amplitude and frequency scaling and phase offset on all outputs
  • Phase sensitive or frequency selective voltage, current power and impedance measurements
  • Frequency response and distortion analysis
  • Front panel configuration lockout for dedicated production and QC test applications
  • Can be configured to emulate older analog PAVs that exist in the market

  • Model 6000

  • Wide bandwidth (0.1Hz – 100kHz)
  • 0.05% basic amplitude accuracy
  • 0.05° phase accuracy
  • Total & Individual harmonic analysis
  • 100ppm accuracy, 1ppm resolution, frequency measurements
  • 4-line scrollable (50 lines total) display and 101 element multimeter
  • Separate amplitude and frequency scaling and phase offset on all outputs
  • Phase sensitive or frequency selective voltage, current power and impedance measurements
  • Frequency response and distortion analysis
  • Front panel configuration lockout for dedicated production and QC test applications
  • Can be configured to emulate older analog PAVs that exist in the market

Specifications

General Specifications – For Full Specifications contact Vitrek

Model 6250

VOLTAGE INPUTS

Amplitude: 0.05% + 0.005%/kHz for any single input and for matching between any inputs multiply by 2 for voltages in excess of 300Vpk
Phase: 0.05° + 0.005%/kHz between A and B on same range, + 0.0025°/kHz per range when differing ranges, + 0.05°/kHz between unpaired inputs, multiply by 2 for voltages in excess of 300Vpk
Noise: 20nV + 0.00001% of full-scale range/√Hz of measurement bandwidthDC Offset:100μV + 0.03% of full-scale range
Distortion: -80dB at any harmonic
Voltage Range: 10mV to 1000Vpk full scale (10Vrms max for 50Ω input) in 3:1 steps. Fixed or auto range
Trigger Level: Zero, TTL, ECL, CMOS, or Variable. 1% of input range accuracy Bandwidth: >2.5MHz or user-defined upper limit in the range of 5Hz to 100kHz (-3dB)
Configuration: Balanced Differential BNC input pairs with separate Guard binding posts. DC + AC or AC only coupling (0.1Hz cut off). Guard may be externally driven or internally connected to either input LoImpedance: 600kΩ to Guard from each input node, selectable 50Ω input impedance, in parallel with less than 35pF
Common Mode: Guard isolated from ground (100MΩ | | 1000pF) for voltages <1000Vpk. Inputs may have voltages to Guard of up to the larger of the range full-scale value or 10V. CMRR referred to Guard is >80db for frequencies up to 10kHz, decreasing linearly to >60dB at 100kHz. CMRR referred to ground is >140dB at DC to 10kHz, decreasing linearly to >100dB at 100kHz

Current Inputs
Current inputs are as voltage inputs with an internal current shunt, yielding full-scale current ranges of up to 300mA peak in 3:1 steps. Maximum burden is 250mV External shunts may optionally be used on the voltage inputs to extend the current ranges up to 20A RMS

PHYSICAL
Power:
80 – 265 Vrms autoselect, 40 – 400 Hz @ 25VA max
Size: 7”h x 17”w x 14”d
Weight: 20 lbs
Operating Range: 0°C to 50°C, less than 85% RH at 40°C (non-condensing)
Storage Range: -30°C to +65°C, less than 95% RH at 40°C (non-condensing)

WARRANTY
Two Years


Model 6000

Voltage Inputs
Amplitude: 0.05% + 0.005%/kHz for any single input and for matching between any inputs multiply by 2 for voltages in excess of 300Vpk
Phase: 0.05° + 0.005%/kHz between A and B or C and D on same range, +0.0025°/kHz per range when differing ranges, + 0.05°/kHz between unpairedinputs (i.e., A and C), multiply by 2 for voltages in excess of 300Vpk
Noise: 20nV + 0.00001% of full-scale range/√Hz of measurement bandwidth
DC Offset: 100μV + 0.03% of full-scale range
Distortion: -80dB at any harmonic
Voltage Range: 10mV to 1000Vpk full scale (10V RMS max for 50Ωinput) in3:1 steps. Fixed or auto range
Trigger Level: Zero, TTL, ECL, CMOS, or Variable. 1% of input range accuracy
Bandwidth: >2.5MHz or user-defined upper limit in the range of 5Hz to100kHz (-3dB)
Configuration: Balanced Differential BNC input pairs with separate Guard binding posts. DC + AC or AC only coupling (0.1Hz cut off). Guard may beexternally driven or internally connected to either input Lo
Impedance: 600kΩto Guard from each input node, selectable 50Ωinputimpedance, in parallel with less than 35pF
Common Mode: Guard isolated from ground (100MΩ| | 1000pF) for voltages<1000Vpk. Inputs may have voltages to Guard of up to the larger of the rangefull-scale value or 10V. CMRR referred to Guard is >80db for frequencies up to10kHz, decreasing linearly to >60dB at 100kHz. CMRR referred to ground is>140dB at DC to 10kHz, decreasing linearly to >100dB at 100kHz

Current Inputs
Current inputs are as voltage inputs with an internal current shunt, yieldingfull-scale current ranges of up to 300mA peak in 3:1 steps. Maximum burdenis 250mV External shunts may optionally be used on the voltage inputs to extend the current ranges up to 20A RMS

Physical
Power: 80 – 265 Vrms autoselect, 40 – 400 Hz @ 25VA max
Size: 7”h x 17”w x 14”d
Weight: 20 lbs
Operating Range: 0°C to 50°C, less than 85% RH at 40°C(noncondensing)
Storage Range: -30°C to +65°C, less than 95% RH at 40°C(noncondensing)

Warranty
Two Years

Ordering & Accessories

Below prices in US$ are for destinations in North America with terms of prepay, net 30 days (OAC) and accepted credit cards. For shipment beyond North America or terms beyond 30 days, please contact the factory for a quotation. If you require rush/expedited shipment please contact Vitrek at (858) 689-2755 or email info@vitrek.com

Phase Angle Voltmeters

Phase Angle Voltmeters – Options & Accessories

Rentals

The 6250/6000 Series Phase Angle Voltmeter and accessories are available for rent. Please contact the factory for a rental quotation on the items and period of time you desire. Vitrek offers a generous rental allowance for rentals that are converted to a purchase and rentals of 12 months come with a 10% buyout.

6250 Series Downloads

* This application displays 13 of the most popular 6250 PAV measurements plus the voltage waveforms for both inputs on a single screen.

* 6250 Firmware Upgrade – There is no field upgradeable firmware for this product.

6000 Series Downloads

* 6000 Series Firmware Upgrade – There is no field upgradeable firmware for this product.