LV3-8R

$587.00

3kV Single Input Bus 8 Output Card with Red Banana Jack Terminals. Comes with: 8xRed Male Sheathed Banana Connectors.

The 964i High Voltage Switching System is built precisely to meet Your HV Switching requirements

964

The 964i holds up to 8, eight channel HV switching cards. That’s up to 64 test points in a single mainframe – multiple units can be combined to increase capacity

Whether you have to hipot an 8 pin connector, a 64 conductor cable or an entire tray of SMD capacitors – the 964i has the capacity to automatically route test points to your tester, so you don’t have to. The 964i is easily configured to handle your test specifications. First, select from 4 different voltage ratings – 3KV, 7KV, 10KV and 15KV. Next, decide on how many cards you need. And finally – choose the input, either + (HV bus) or – (return bus) for each card. It’s that simple. If you have any questions, contact a Vitrek application specialists for assistance in configuring your ideal switching solution.

High Voltage Switching doesn’t get any easier

The 964i is simple to set up. Standard front inputs connect directly to your Hipot/Continuity Tester and up to 60 rear panel terminals connect with your test fixture or DUT. Up to four 964i’s can be controlled directly by a single Vitrek 95X or V7X Series Hipot Tester or up to 10 via PC through the 964i’s built-in RS232 (serial) port or available GPIB interface. The 964i’s LCD display confirms system status and switch activation at a glance.

Try the 964i High Voltage Switching Scanner, you will never manually switch again

The Vitrek 964i High Voltage Automated Test Switching System routes high voltage test signals and return signals to any desired test points. This unique capability gives you control over each individual relay, unlike typical cable testers which restrict you to a fixed pattern. With available mux cards, you can also access the matrix with other equipment such an LCR meter or DMM. The result is a highly repeatable, rapid switching test system with no operator intervention and fully automated data acquisition. With voltage switching capability up to 15,000 volts or current switching as high as 40 amps – the 964i can handle just about any test requirement that comes along. Give it a try, you will never switch back to manual testing again.

964i rear panel 50K res

“The 964i rear panel accommodates up to 60 output terminals. Unit shown above with 16 + terminals (HV) and 16 – terminals (return). The 964i ships with mating connectors for all +/- HV terminals 7KV and higher. Custom length HV lead sets are optionally available.”

Product Features and Benefits

  • High Voltage Ratings to 3KV, 7KV, 10KV or 15KV
  • High Current Ratings to 40 Amps
  • Reduces hazardous operator exposure to high voltage
  • Improves test quality, consistency and repeatability
  • Enhances end product quality and reliability
  • Up to 64 channels in a single compact unit
  • Vitrek multi-conductor Hipot Tester control ports and RS232 interfaces standard
  • GPIB optionally available
  • May be controlled directly by Vitrek Hipot Tester
  • Available QuickTest™ graphical software with full data aquisition
  • CE mark certified to EN 61010
  • Made in the U.S.A.

Specifications

HV Series Relay Boards

Max Voltage
(Between any two connections or ground)
HV7: 7KVDC 5KVAC, HV10: 10KVDC 7KVAC, HV15: 15KVDC 10KVAC
Frequency: <500Hz. Carrying Current: Switching Power: HV7 and HV10: Switching Time: Expected Life: <1mA, Contact Resistance: At terminals, <50% expected life operations (add 0.1Ω for <100% life) <0.25Ω (uncompensated), <0.1Ω (compensated), <±0.1Ω difference between lowest and highest. Leakage Resistance: Any individual connection to ground: >500GΩ at 100GΩ at 1TΩ at <30C. Leakage Capacitance: Any individual connection to ground: 15pF (typical). Common connection to ground: 50pF (typical). Between any two connections: 5pF (typical).
Thermal EMF: <1mV. Coil Power: Holding closed: 0.3W (typical), Closing: 1.25W for 5ms (typical)

LV Series Relay Boards

Max Voltage
(Between any two connections) 3KVDC 2KVAC
(between any connection and ground) 5KVDC 3KVAC
Frequency: <500Hz. Carrying Current: Switching Power: Switching Time: Expected Life: <1mA, Contact Resistance: At terminals, <50% expected life operations (add 0.05Ω for <100% life) <0.175Ω (uncompensated), <0.05Ω (compensated), <±0.075Ω difference between lowest and highest. Leakage Resistance: Any individual connection to ground: >1GΩ at 200MΩ at 1GΩ at <30C. Leakage Capacitance: Any individual connection to ground: 15pF (typical). Common connection to ground: 50pF (typical). Between any two connections: 10pF (typical).
Thermal EMF: <200uV. Coil Power: Holding closed: 0.12W (typical), Closing: .5W for 5ms (typical)

HC Series Relay Boards

High Current Relay Specifications –

Max Voltage:
Between any two connections: 1.5KVdc/1KVrms.
Any connection to ground: 1.5KVdc/1KVrms.
Frequency: <500Hz. Carrying Current: Switching Power: Min Switching Current: >0.5Arms.
Switching Time: Expected Life: 1 to 10Arms resistive 500,000 operations. At max power: 10,000 operations.
Contact Resistance: <0.025Ω (at terminals, <100% expected life operations). Leakage Resistance: Any individual connection to ground: >20MΩ at 5MΩ at 20MΩ at <30C. Coil Power: Holding closed: 0.6W (typical), Closing: 2.5W for 25ms (typical)

Low Current Relay Specifications –

Max Voltage: Between any two connections: 1.5KVdc/1KVrms. Any connection to ground: 1.5KVdc/1KVrms.
Frequency: <500Hz. Carrying Current: Switching Power: Switching Time: Expected Life: <1mA, Contact Resistance: At terminals, <50% expected life operations (add 0.05Ω for <100% life), <0.15Ω (uncompensated), <0.05Ω (compensated). Leakage Resistance: Any individual connection to ground: >100GΩ at 10GΩ at 100GΩ at <30C. Leakage Capacitance: Any individual connection to ground: 15pF (typical). Common connection to ground: 50pF (typical). Between any two connections: 10pF (typical)
Thermal EMF: <100uV. Coil Power: Holding closed: 0.06W (typical), Closing: 0.25W for 5ms (typical)

General Specifications

Relay Card Capacity: Eight cards
Front input Terminals: 5 inputs terminals
Rear Panel Terminals: 60 terminals
Interfaces:RS232 and VICL (Vitrek Hipot Control) standard, GPIB optional
Nominal Dimensions: 89mmH x 432mmW x 457mmD (3.5” x 17” x 18”)
Nominal Weight: Mainframe only 3.5Kg (8lb) net, 7Kg (16lb) shipping. Add 0.75Kg (1.5lb) per relay card
Storage Environment: -20 to 75C (non-condensing)
Operating Environment: 0 to 50C, <85% RH (non-condensing), Pollution Degree 2 Operating Altitude: 0 to 10000ft ASL
Line Power: 105-265Vrms, 45 to 450Hz, Category II using provided external power module

Ordering & Accessories

Below prices in US$ are for destinations in North America with terms of prepay, net 30 days (OAC) and accepted credit cards. For shipment beyond North America or terms beyond 30 days, please contact the factory for a quotation. If you require rush/expedited shipment please contact Vitrek at (858) 689-2755 or email info@vitrek.com

Pre-Configured Systems

Custom Configured Systems

964i High Voltage Switching System Accessories

Rentals

The 964i High Voltage Switching System and accessories are available for rent. Please contact the factory for a rental quotation on the items and period of time you desire. Vitrek offers a generous rental allowance for rentals that are converted to a purchase and rentals of 12 months come with a 10% buyout.

964i High Voltage Switching System Downloads

*At the end of your FREE 45 day trial of QT Enterprise software, you must purchase a Software License Key for the appropriate products the software is being used with.  See ordering information or contact Vitrek for details at info@vitrek.com (858) 689-2755.