2802 Two Channel Power Analyzer – Internal & External Current
All 280X power analyzers have IEEE488, RS232 and USB interfaces as standard.
$4,720.00
2802 Two Channel Power Analyzer – Internal & External Current
All 280X power analyzers have IEEE488, RS232 and USB interfaces as standard.
2802 Two Channel Power Analyzer-Internal & External Current
All 280X power analyzers have IEEE488, RS232 and USB interfaces as standard.
Weight | 15 lbs |
---|---|
Dimensions | 15 × 15 × 8 in |
With an extended measurement range from micro-amps to hundreds of amps and millivolts to kilovolts, the 2801 & 2802 are the ideal analyzers for standby power or Energy Star testing. In addition to numerical results, the 2801 & 2802 captures waveforms with true 512-point precision. Results and waveforms can be displayed, read via communication ports or sent directly at full resolution to a USB printer. Power and amplitude measurements with an accuracy of <0.1% are automatically synchronized to the fundamental frequency. Peak, RMS, rectified and DC measurements of voltage, current and power are provided including continuous, inrush, startup and history modes, plus an integration mode for W-Hr, A-Hr, VA-Hr as well as integrated average power. (Channels can be operated synchronously or independently on the 2802). The 2801 and 2802 also provide waveform peak and glitch capture modes.
Accuracy specifications valid for one year for ambient temperatures within 5 °C of calibration temperature.
Voltage Range (Measureable): 2000V (850Vrms) max. continuous
Internal Current Range (Measurable): 150Apk (30Arms) max. continuous
External Current Transducers (Measurable): 35Vpk (15Vrms) max. continuous
Voltage & Current Accuracy: See charts below
Frequency Measurement Accuracy: 0.005%
Crest Factor Accuracy: V: (50mV + 0.01% of pk rng)/RMS value A: 50uA + 0.01% of pk rng)/RMS value
Harmonic Accuracy (Voltage & Current): 0.02%
Waveforms: Actual, Peak Capture, Distortion and Glitch Capture
Charts, with Zoom & Scroll: History, Startup and Inrush
Line Switch
Max Open Voltage: 720Vpk (480Vrms)
Max Surge Current: TBD
Max On Current: 10Arms
Turn On Phase: 1° resolution
Digital Interfaces: GPIB (IEEE-488), USB (host and device), RS-232, Digital IO
Physical
Power Input: 12VDC @ 1.5A minimum output
Size: (HxWxD) 4.7″ x 13.8″ x 9.5″ (11.94cm x 35.05cm x 24.13cm)
Weight: 7.5 lbs
Operating Range: 0°C to 55°C, less than 95% R.H. (non-condensing)
Storage Range: -20°C to 670°C, less than 95% R.H. (non-condensing)
Unit is supplied with one Vitrek T5 universal external power supply, 100-240Vrms, 50-60Hz, with a 2.5mm 12VDC output plug and a three-prong IEC320 AC inlet receptacle, plus a three-prong AC power cord.
Warranty: Two Years
3.8M zip file – This zip file contains the latest 280x USB driver for 32-bit operating systems. This file includes the DLL. 01 Apr 2009
3.9M zip file – This zip file contains the latest 280x USB driver for 64-bit operating systems. This file includes the DLL. 01 Apr 2009
This PDF lists the function calls to the DLL 12-June-2012
470k, USB, LabView 8.6.1 – This software displays many of the 280x parameters on a single screen, allows for snapshot recording of the data or continuous logging of data to an Excel-compatible file. It also displays the harmonics and distortion graphs.
560k, USB, LabView 8.2 – This XView software is based on LabView 8.2. It automates the data collection and reporting for the ENERGY STAR Program Requirements for Computers: Version 4.0 – 19 Sept 08
492k, USB, LabView 8.2- This XView software is based on LabView 8.2. It automates the data collection and reporting for the ENERGY STAR Program Requirements for Consumer Audio and DVD products. The zip file also includes the ENERGY STAR requirements document. 02 July 2007
281k, USB, LabView 8.2- This XView software is based on LabView 8.2. It automates the data collection and reporting for the ENERGY STAR Program Requirements for single-voltage, external AC/DC and AC/AC power supplies.
167k, USB, LabView 8.2- This XView software is based on LabView 8.2. It automates the data collection and reporting for the ENERGY STAR Program Requirements for 03 Nov 2008