MTI’s Accumeasure HD Amplifier vs. SmarAct’s PicoScale Interferometer
MTI's Accumeasure HD Amplifier vs. SmarAct's PicoScale Interferometer Research & Development Piezoceramic, 1-3 Pzt / Polymer Composite And Pvdf Film Amplitude Description This application note compares MTI's Accumeasure HD amplifier to SmarAct's Picoscale interferometer in terms of resolution and accuracy for very small displacement measurements. Specifically, this comparison focuses on minimum expected resolution and the effects of noise on accuracy. High resolution interferometers are widely regarded as the instrument of choice for the type of measurements described in this application note, but MTI's technology provides exceptional accuracy and stability. Moreover, the [...]
MTI Presale Inquiry Form
MTI Instruments' team of experts looks forward to supporting your next application. Feel free to use this form to contact our sales staff for pre-sale support including, application information, pricing, delivery, etc. If you need immediate assistance please feel free to contact us via phone at (815) 838-0005. Pre-Sale Inquiry MTI Instruments, Inc. 900 N. State Street Lockport, IL 60441 USA | Map It Toll-Free: +1-800-342-2203 Tel: +1-518-218-2550 Fax: +1-518-218-2506
Ideal Charge Amplifier for Piezoelectric Sensor
Ideal Charge Amplifier for Piezoelectric Sensor Aviation (Turbine Engines), Automotive Research and Development, Industrial Manufacturing Vibration Monitoring: Turbine Engines; Vehicle Testing Pressure Monitoring: Combustion Engines; Pumps, Turbines Amplitude Measurements:  Acceleration, Vibration, Pressure Description Ideal Charge Amplifier for Piezoelectric Sensors Piezoelectric sensors, such as accelerometers for turbine vibration measurement and pressure transducers for combustion dynamics monitoring (CDM), generate a high-impedance charge output. This output requires proper conditioning and amplification before it can be transmitted over system cabling to measurement instrumentation. This is where a charge amplifier for piezoelectric sensors also known [...]
MTI-Website Accumeasure Solutions Google Ads
Please complete the form below to request information on MTI Instruments Products. MTI Instruments by Vitrek 900 N. State Street Lockport, IL 60441 Phone: (800) 342-2203 Outside North America: (518) 218-2550 Fax: (518) 218-2506 sales@mtiinstruments.com
Vibration and Balancing Systems: The Spectrum Plot
The Spectrum Plot: Types of Aircraft Vibration One of the least understood features of the PBS series of vibration analyzers is the spectrum function. The spectrum functionality is a more difficult function to understand, but once mastered, technicians can quickly develop an extremely in-depth understanding on what is going on in an engine during a test. Figure 1, below, shows a basic spectrum from the PBS system. On the x-axis is frequency, measured in Hz (per second). On the y-axis is amplitude, measured in units of velocity, inches per second pk, or IPS pk. Figure 1: Basic Spectrum [...]
MTI-Website 1510A Google Ads
Please complete the form below to request information on MTI Instruments Products. MTI Instruments by Vitrek 900 N. State Street Lockport, IL 60441 Phone: (800) 342-2203 Outside North America: (518) 218-2550 Fax: (518) 218-2506 sales@mtiinstruments.com
Capacitive vs. Eddy Current Sensors: A Comparison for Non-Contact Measurement
Capacitive vs. Eddy Current Sensors: A Comparison for Non-Contact Measurement Capacitive vs. Eddy Current Sensors: A Comparison for Non-Contact Measurement Manufacturing Ev Battery Production Thickness, Distance This application note from MTI Instruments compares two widely used types of non-contact sensors: eddy current sensors and capacitive sensors. It covers their basic operating principles, provides a quick comparison, and offers guidance for selecting the right sensor for your application. Capacitive Sensors: Operating Principles and Applications Capacitive sensors use electric fields to measure the distance between the sensor face and the target surface. These sensors are particularly effective [...]
Thickness Measurement of Dielectric Materials
Thickness Measurement of Dielectric Materials Manufacturing EV Battery Production Thickness, Distance --- Description --- Introduction Many applications, both in manufacturing and research, require precise material thickness measurements. This becomes especially difficult if the material is moving, is non conductive and/or translucent to clear. The specifics of your application may make accurate measurements difficult; many circumstances prohibit contact measurement, and make laser measurements difficult or impossible, for example with thin clear materials such as glass, sapphire, plastic . In cases such as these, capacitance measurement provides a highly accurate and cost-effective solution. [...]
MTI-DEMOADV – Application Review/Product Demo Request
Please complete the form below to request information on MTI Instruments Products. MTI Instruments by Vitrek 900 N. State Street Lockport, IL 60441 Phone: (800) 342-2203 Outside North America: (518) 218-2550 Fax: (518) 218-2506 sales@mtiinstruments.com
Foam Density Measurement: Capacitance Sensors vs. Nuclear Gauges
Foam Density Measurement: Capacitance Sensors vs. Nuclear Gauges Foam Density Measurement Manufacturing EV Battery Production Thickness, Distance This application note from MTI Instruments compares two technologies for measuring foam density: capacitance sensors and nuclear gauges. It examines the basic operating principles of each technology and explains why capacitance measurement is recommended for in-line measurement during foam manufacturing. Capacitance Sensors Capacitive probes are non-contact devices that use electric fields to measure foam density. In combination with a thickness value, a density measurement may be calculated. These probes consist of a capacitance [...]