MTI Application Note: Testing for Connector Failure Due To Vibration or Shock
Testing for Connector Failure Due to Vibration or Shock Mobile Communications Equipment Needs Reliable Connectors That Will Not Disconnect with Shock or Vibration Introduction A large multinational company approached MTI to provide a sensor capable of measuring displacement that also wouldn’t load the target (connector). Shock and vibration testing would span 2-15G and the target connectors were very small. Application MTI’s 2100 optical displacement sensor system is ideal for this kind of application because very small probes can be used and they measure displacement via reflected light. [...]
TESTING CHARGE AMPLIFIER GAIN AND FREQUENCY RESPONSE WITH A SIGNAL GENERATOR
[Application Note 40518] Piezoelectric transducers produce small electrical charges in response to pressure. Their sensitivity, ruggedness, and stability at high temperatures make them an essential building block of many accelerometers and pressure sensors. Applications include turbine vibration measurement (accelerometers) and combustion dynamics monitoring (pressure sensors). Typically, the high-impedance charge output produced by a piezoelectric transducer must be conditioned and amplified before transmission across system cabling to the data acquisition and measurement instrumentation. This conversion is accomplished with a device called a charge amplifier. Problem Over time, a charge amplifier’s signal response can drift. Damage to the charge amplifier or associated [...]
MTI Whitepaper: Easy Roller Gap Measurement Ensures Calendering Success
Easy Roller Gap Measurement Ensures Calendering Success Many roll-to-roll finishing processes typically use a calender, or series of hard pressure rollers, to deliver smooth, high-quality products of plastic, textile, or paper (Fig 1). Ensuring a consistent material thickness, however, depends on the ability to monitor, and maintain, a precise gap between rollers. This application note describes a quick and easy means for roller gap measurement Problem Establishing a roller gap and checking for parallelism across roller width can be a slow and cumbersome procedure. Manual measurement requires multiple sized feeler gauges which can introduce errors. Misinterpreting [...]
THICKNESS INFORMATION OF COMPOSITE MATERIALS
Composite materials consist of two or more materials which include a substrate or base material such as paper, cotton cloth, or glass cloth along with a resin or adhesive such as epoxy, melamine, or silicone. To make a thermoset laminate, the base material is coated with the adhesive so that layers of material can be pressed under heat and pressure into sheet form. The Problem: Composite material thickness needed to be verified prior to forming or machining. Due to the size of the sheets typical measurement techniques were not suitable. A consistent method to accurately measure the board thickness [...]
Application Note: How to Ensure Your LED Lighting Products Meet Industry Standards
Testing for performance, energy effeciency, consumption verification, quality and safety compliance during product development. Introduction Manufacturers and users of LED lighting products need to ensure that their products meet the qualifications and requirements of a multitude of reliability and efficiency standards. In addition to voluntary initiatives and programs like EnergyStar, mandatory standards and specifications for the lighting industry must be kept in mind during project development, including the latest IES LM-79-19 and the ANSI C82.16 documents. This application note provides an overview of relevant lighting standards and specifications for LED lighting products. [...]
GaGe Application Note: Creating a Data Link Signal Integrity Test Platform
Download a PDF Copy of this App Note Data Link Device Testing The data link device under test (Figure 1) is characterized by comparing test signals that are input to the link with signals measured at the link output. Differences between these two test signals indicate a degradation by the link during transmission. Figure 1. Two test platforms (PCIe and PXIe, respectively) transmit and receive the data link test signals. GaGe RazorMax high-speed data acquisition cards record the data for signal integrity comparison. The input and output test signals require sampling at 1 GS/s (GigaSample per second) [...]
TIRE TREAD INSPECTION WITH 1D LASER SENSOR
Tire manufacturers wants to satisfy their customers, and protect themselves from liabilities, manufacturers are moving to 100% tire inspection for defects and abnormalities. Defects not only cause potential safety issues but they can also introduce unwanted vibration into the vehicle suspension system. Belts can be overlapped, or not cover the complete tire surface, causing weak or bubbled areas and imbalances. The tread depth can be too shallow, leading to decreased service life. An uneven tire can cause excessive runout and vibration. MTI was approached by a major manufacturer requesting a solution to measure tread depth, runout and blistering. They [...]
Article: Advanced Test Equipment Enables LED Lighting Manufacturers to Ensure Compliance with Standards-August, 2022-Designing-Electronics.com
Download a PDF Copy of this Article Download a PDF Copy of this Article
Torque Converter
Industry Automotive Applications Torque Converter Measurement Type Surface Description Since minute defects in the torque converter casing wall thickness can result in unacceptable and dangerous torque converter expansion, a precision measurement system was needed to measure the impeller hub displacement and thus the torque converter axial displacement. An AC dynamometer would be required to spin the torque converter at a high rate of speed while a fast response hydraulic system is needed to pressurize the converter to pressures up to 150 psi. MTI’s MicroTrak laser sensor was selected because it offered [...]





