Legacy Software-GaGe
GaGe Product Legacy Drivers & Software CompuScope Drivers : 32-bit and 64-bit Hardware Device Drivers GaGeScope : Windows PC Oscilloscope Application SDK for C/C# & Python : 32-bit and 64-bit Software Development Kit for C/C# and Python SDK for LabVIEW : 32-bit and 64-bit Software Development Kit for LabVIEW SDK for MATLAB : 32-bit and 64-bit Software Development Kit for MATLAB Utility Applications : GaGe Viewer, Legacy Clean, Signal File Conversion, & GaGe File Converter Manuals : Hardware and Software Manuals Windows Version Release Date Release Notes File Size File Download 5.06.24 11/09/2023 394 MB CompuScope-v5.06.24.zip NOTE: Run the [...]
MTI App Note: Step Height Measurement (Thickness) of Copper Foil or EV Battery Film on a Roller Rig
Step Height Measurement (Thickness) of Copper Foil or EV Battery Film on a Roller Rig Leverage MTI Instruments' digital Accumeasure system to measure the thickness of the material used as anode and cathode plates in rechargeable Li-Ion battery cells Introduction Figure 1. Simplified structure of a Li-Ion battery cell This white paper describes, in detail, how Non-Contact Measurement systems can be used to measure the thickness of the material used as anode and cathode plates in a rechargeable Li-Ion battery Cell. Figure 1 describes the elements comprising a Li-Ion battery cell. The cathode is comprised of [...]
Technical Support Request
Request for Pricing / Quotation / Application Engineer Contact Speak to an Application Engineer: 1-800-567-GAGE Fill out my Wufoo form!
Automotive Engine Controller Monitoring
Automotive Engine Controller Monitoring Customer Case The customer is a major electronics manufacturer who wants to find a cost effective replacement to VXI digitizers in testing automotive engine control signals. The requirement is for several ATE stations. Each one will require 4 single-ended channels or 2 "true differential" channels, 4 MHz of input analog bandwidth (mostly single shot) with voltage ranges from 0.05 to 70 volts. The digitizers must have at least 12 bits of vertical resolution, 0.5% accuracy and ½ MegaSample per channel of acquisition memory. The customer would like to operate the station under a controlling LabVIEW [...]
Fiber Optic Automated Measurement System
Fiber Optic Automated Measurement System Customer Case The customer is in the business of developing lasers and LED components for fiber optic data \ telecommunications applications. The requirement is for an automated test system to monitor the pulse characteristics of the laser. The customer will require 3 channels at high vertical resolution due to the fact that some variances in amplitude will be only 1 mV and need to be detected. The goal is to capture 10,000 samples per channel at 50 MegaSamples per second with a 1 KHz to 5 KHz Pulse Repeat Frequency (PRF). The customer would [...]
MTI Application Note: How to Achieve <1um Accuracy When Measuring Roller Gap
How to Achieve <1um Accuracy When Measuring Roller Gap Roller Gap Measurement with MTI Digital Accumeasure Capacitive Probes Many roll-to-roll finishing processes typically use a calender, or series of hard pressure rollers, to deliver smooth, high-quality products of plastic, textile, or paper (Fig 1). Ensuring a consistent material thickness, however, depends on the ability to monitor, and maintain, a precise gap between rollers. This application note describes a quick and easy means for roller gap measurement. Problem How to measure the small gap between rollers to keep track of product thickness. Typically, it’s not possible to [...]
GaGe Application Note: Creating a Data Link Signal Integrity Test Platform
Creating a Data Link Signal Integrity Test PlatformThis application note describes how a manufacturer of data links utilizes GaGe Instruments’ PC-basedhigh-speed data acquisition digitizers to perform production-level signal integrity testing. Data Link Device Testing The data link device under test (Figure 1) is characterized by comparing test signals that are input to the link with signals measured at the link output. Differences between these two test signals indicate a degradation by the link during transmission. The input and output test signals require sampling at 1 GS/s (GigaSample per second) with at least 14-bit vertical resolution. Both signals must [...]
MTI Application Note: Security of Flight Doors Improved Through Use of MTI-2100 Fotonic Sensor
Security of Flight Doors Improved Through Use of MTI-2100 Fotonic Sensor Increased Safety & Reliability for Aircraft Cockpit Doors NTSB safety records point to numerous incidents involving cockpit door locking/unlocking mechanisms, either accidentally opening/closing or not operating fact enough upon command. Learn how one key industry supplier leveraged Fotonic Sensors to increase reliability and safety for their door locking mechanisms. Introduction Figure 1. Example of a typical cockpit door strike NTSB safety records point to numerous incidents involving cockpit door locking/unlocking mechanisms, either accidentally opening/closing or not operating fast enough upon command. In the assembly [...]
Test & Measurement
Test & Measurement The following example case studies demonstrate how GaGe products and services have been successfully applied in various data acquisition test & measurement applications. We encourage you to contact us and discuss your application in more detail with our engineering team. GaGe can provide tailored custom hardware and software solutions to meet specific application requirements. Electronics / Device Testing Wireless Phone Chip Testing Fiber Optic Automated Measurement System Automotive Engine Controller Monitoring Digital I/O ASIC Testing Treadmill Power Glitch Monitoring Automatic Accelerometer Calibration System MEMS-Based High Throughput Screening Disk Drive Track Scanning Video [...]
MTI Product Development Overview Video
View this quick video to learn how MTI's engineering team develops new products from prototype to finished product!