Laser Scanning for Eye Diseases

Laser Scanning for Eye Diseases Customer Case In scanning for non-ablative eye diseases, the customer has a requirement for high vertical resolution while remaining cost effective. By shooting a low-powered laser into the eye (low enough to not cause lasting damage), they are able to determine whether there are any problems in the eye cells. The laser does cause minute damage that is repaired by the antibodies of the eye. The requirement is to capture laser reflections and analyze them. The scan takes place over the entire eye and there are therefore multiple acquisitions. The main obstacle is that [...]

By |March 12th, 2023|Comments Off on Laser Scanning for Eye Diseases

White Paper: Precision Power Analyzers

White Paper  All the tools needed to study and optimize virtually any power project in a single instrument Introduction The design of any power conversion system requires the measurement of a large range of electrical parameters that could be made using a lab bench full of instruments. The precision power analyzer pulls all of these measurements into a single instrument replacing meters, oscilloscopes, chart recorders, harmonic analyzers and other devices. This paper will provide a basic overview of the functions and capabilities of high-performance power analyzers. Examples of these functions and how to apply [...]

Echocardiography Experiment

Echocardiography Experiment Customer Case This customer is involved in an Echocardiography experiment. The customer already has an ultrasound imager with a built-in A/D converter which can output 12-bit image data which must be analyzed with the customer's proprietary algorithms on a PC platform. In order to accomplish this, it is required to bring 12-bit digital data at 35 MHz clock rate into a PC. This data is arriving in a burst mode with a repeat frequency of 12.8 KHz with 1000 samples arriving in 28 us followed by no data for the next 50 us. There are 512 such [...]

By |March 12th, 2023|Comments Off on Echocardiography Experiment

MTI Instruments is making its global presence known in Singapore

Click Here to View Ways to Use 1510A with the PBS-4100+ Join MTI Instruments at the Singapore Expo Convention and Exhibition Centre from September 24th to September 26th, 2019.  Visit MTI Instruments in Booth #756  at the premiere event in Asia Pacific for the commercial air-transport maintenance, repair and overhaul (MRO) industry, to see its PBS-4100 line of vibration and balancing systems. Aircraft engine vibrations caused by out-of-balance parts can lead to cracked fan, turbine, and compressor components. Imbalance-induced vibrations can also cause metal fatigue and, if left unchecked, engine failure. Pinpointing the source of vibrations can be challenging [...]

By |September 3rd, 2019|Categories: Blog, Brand-MTI, News-MTI, z1|Comments Off on MTI Instruments is making its global presence known in Singapore

Ultrasound Imaging

Ultrasound Imaging Customer Case This customer's application involves capturing ultrasound echoes from a medical imaging system, to be used in bedside monitors, defibrillators, intervascular ultrasound, ECG, etc. The live imaging rate is 30 frames per second (fps). Each image frame depicts a full 360-degree circular section. A frame is 240 echoes, so the pulse repeat frequency (PRF) is 7200 Hz, or one echo every 140 us. The customer anticipates signals at 50 MHz with a 50% bandwidth (the passband must extend to at least 75 MHz). The echo duration is 15 us; the signal size is roughly +/- 70 [...]

By |March 12th, 2023|Comments Off on Ultrasound Imaging

How to Reduce Inconsistent Wafer Measurements

How to Reduce Inconsistent Wafer Measurements Avoid 5 Common Mistakes That Destroy Wafer Measurement Accuracy You take pride in your work. You’re precise, accurate and depend on the right metrology equipment. Then why are your bare semi-conductor wafer measurements sometimes inconsistent? It may be something you’re doing (or not doing) — without realizing it. MTI Instruments discovered there are five common mistakes that engineers and users make with bare semi-conductor wafers. The “Five Mistakes Made When Taking Semiconductor Wafer Measurements” Tech-Brief details these all-too-typical errors that adversely impact measurements. [...]

By |August 29th, 2019|Categories: Application Notes-MTI, Brand-MTI, Industry-Electronics, Industry-Semiconductor, Industry-Semiconductor-MTI, ZOK|Comments Off on How to Reduce Inconsistent Wafer Measurements

Ultrasonic Imaging

Ultrasonic Imaging Customer Case The customer is digitizing signals returned from an ultrasonic transducer used in the study of cardiac phenomena. At the moment, a 5 MHz transducer is being used, but the customer wants to upgrade to a 10 MHz transducer in the near future. This transducer will give him better spacial resolution. The customer needs one channel of very fast (100 MSPS), preferably 12-bit A/D conversion which is controlled by an external trigger signal. Bandwidth of the analog front-end of the A/D card or system must be very flat up to 15 or 20 MHz. The application [...]

By |March 12th, 2023|Comments Off on Ultrasonic Imaging

Ultrasound Tissue Imaging

Ultrasound Tissue Imaging Customer Case This customer is building a system to be used as a test station for examining human tissue for disease. Diseased organs differ from healthy organs in ways that can be measured via the echoes of ultrasound transmissions which are passed through the tissues. The customer's system will build a 3D image of the tissue under examination. In order to obtain a clear ultrasound image of the object being studied, the successive data captures have to be aligned to eliminate a distorted image. Jitter which would result from an asynchronous triggering is not acceptable. The [...]

By |March 12th, 2023|Comments Off on Ultrasound Tissue Imaging

Vitrek featured in Bodo’s Power Systems

Click here to Download a copy of this article! Click here to Download a copy of this article!

By |August 13th, 2019|Categories: Articles-Vitrek, Brand-Vitrek, Industry-Electronics, Industry-Energy, Industry-Manufacturing, Industry-R&D, News-Vitrek, z1|Comments Off on Vitrek featured in Bodo’s Power Systems

Ultrasonic Medical Imaging System

Ultrasonic Medical Imaging System Customer Case A customer wants to construct an ultrasonic medical imaging system based on a transducer array. A central ultrasonic generation transducer generates a burst of ultrasonic energy which travels towards a tissue specimen. Echoes reflected off the tissue specimen are simultaneously detected by an array of 48 ultrasonic receiver transducers arranged in a dish-like pattern. The customer must simultaneously digitize all 48 signals and download them to PC RAM as quickly as possible. The customer requires 8 bit vertical resolution and would like to sample at 40 MS/s, but 20 MS/s would be acceptable. [...]

By |March 12th, 2023|Comments Off on Ultrasonic Medical Imaging System